Grizzly G0501 Saw User Manual


 
G0501 Sliding Table Saw -15-
Control Panel
A. EMERGENCY STOP Button—Disconnects
power to all motors in the motor cabinet.
B. MAIN BLADE OFF Button—Stops the main
saw blade.
C. SCORING BLADE OFF Button—Stops the
scoring blade.
D. MAIN BLADE DOWN Key—Lowers the
height of the main saw blade.
E. SCORING BLADE RIGHT Key—Moves the
scoring blade right for alignment purposes.
F. SCORING BLADE DOWN Key—Lowers the
height of the scoring blade.
G. C Key—Clears typed entries in the display.
H. Keypad—Keys for inputting the desired
angle of the saw blade.
I. Stop Key—Stops the trunnion movement.
J. Start key—Starts trunnion movement after
an angle has been entered.
K. +” Key—Manually increases the angle of
the saw blades in increments of 0.1˚.
A
N
M
L
K
I
J
B
H
G
C
D
E
F
O
P
Q
T
R
S
L. -” Key—Manually decreases the angle of
the saw blades in increments of 0.1˚.
M. Set Key—Used to set blade angles entered
into the keypad. Also, used for calibration.
N. Digital Display—Displays the current angle
of the saw blades.
O. SCORING BLADE UP Key—Raises the
height of the scoring blade.
P. ARBOR RPM Display—Displays the current
RPM of the saw blades.
Q. SCORING BLADE LEFT Key—Moves the
scoring blade left for alignment purposes.
R. MAIN BLADE UP Key—Raises the height of
the main saw blade.
S. SCORING BLADE ON Button—Starts the
scoring blade. Note—The main saw blade
must be ON for the scoring blade to start.
T. MAIN BLADE ON Button—Starts the main
saw blade.
Figure 8. Control panel close-up.