Grizzly G0501 Saw User Manual


 
G0501 Sliding Table Saw -33-
Test Run
Now that the machine is connected to the power
source, it is important to perform a test run to
make sure all the controls are working properly.
Before starting the saw, make sure you
have performed the preceding assembly
and adjustment instructions, and you have
read through the rest of the manual and are
familiar with the various functions and safe-
ty issues associated with this machine.
Failure to follow this warning could result in
serious personal injury or even death!
To test run the saw:
1.
Put on safety glasses and make sure any
bystanders are out of the way and also wear-
ing safety glasses.
2. Turn the switch on the side of the control
panel to ON. This is the main power switch.
3. At the front of the control panel, rotate the
red EMERGENCY STOP button until it
springs up. The control panel is now live and
any buttons you push will react accordingly.
4. Turn to page 14 and experiment with all of
the controls until you are familiar and com-
fortable with them.
If the blade moves in the wrong direction,
then disconnect the power and switch the
power wires at the circuit breaker in the
electrical box.
If any problems occur, press the EMG
STOP button. Investigate and correct the
problem before operating the machine
further. If you need help, refer to the trou-
bleshooting section in the back of this
manual or contact our service department
at (570) 546-9663.
The remaining adjustments in this section require
you to connect the power cord to the saw and
install a plug on the power cord. Before begin-
ning, read Section 3: Circuit Requirements to
make sure your setup meets the requirements of
the machine.
To connect the saw to the power source:
1. Read through Section 3: Circuit
Requirements to double-check that your
setup follows the safety and circuit require-
ments, and that the power cord you have
chosen meets the minimum requirements for
this machine.
2. Open the control panel box.
3. Feed the power cord through the strain relief
on the side of the control panel, and connect
the cord wires to the main terminal (Figure
53).
4. Close the control panel door.
Figure 53. Main terminal located inside saw
control panel.
5. Connect the power cord to an L15-30 Plug.
Note—You must have an L15-30 receptacle
to use with the L15-30 plug.
Power Cord