Lincoln Electric SVM128-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
INSTALLATION
A-2 A-2
SA-250
TECHNICAL SPECIFICATIONS - SA-250
INPUT - DIESEL ENGINE
Manufacturer Description Speed Displacement Ignition Capacities
Perkins 3 cyl., 4 cycle 1725 RPM 152 cu. in. Electric Fuel: 15 gal.
D3.152 Water-cooled Full load (2500 cc) (57 liters)
diesel
38.2 HP @ 1800 RPM Oil: 7.2 qt.
1725 RPM High idle (6.9 liters)
1350 RPM Water/coolant: 10 qt.
Low idle (9.5 liters)
RATED OUTPUT - WELDER
Duty Cycle Amps Volts at Rated Amperes
100% Duty Cycle 200 DC Constant Current 40V
60% Duty Cycle 250 DC Constant Current 40V
(1)
35% Duty Cycle 325 DC Constant Current 33V
OUTPUT - WELDER AND GENERATOR
Welding Ranges Max. Open Circuit Voltage Auxiliary Power
40-325 Amps DC 98.5 3.0 kVA of 115/230 V, 60Hz Power
26 Amps @ 115 V
(2)
13 Amps @ 230 V
PHYSICAL DIMENSIONS
Height Width Depth Weight
43.1 in. 28 in. 67 in. 1650 lb.
1096 mm 711 mm 1702 mm 742.5 kg
1
Lincoln rating. Nema rating at 60% duty cycle is 250 amps @ 30 V.
2
15 amps can be drawn from either half of the receptacle. Total combined load of all receptacles cannot exceed 3.0 kVA.