PARAMETERS
75
Pr. 20 "acceleration/deceleration
reference frequency"
Pr. 21 "acceleration/deceleration time
increments"
Pr. 79 "operation mode selection"
Pr. 180 to Pr. 186
(input terminal function selection)
Related parameters
4.2.10 Jog operation (Pr. 15, Pr. 16)
Pr. 15 "jog frequency"
Pr. 16 "jog acceleration/deceleration time"
In the external operation mode, jog operation can be started and stopped by the start signal (STF, STR) with
the jog signal ON, after selection of the jog operation function using the input terminal function selection. In
the PU operation mode, jog operation can also be performed using the PU (FR-DU04/FR-PU04).
#
Set the frequency and acceleration/deceleration time for jog operation
Parameter
Number
Factory
Setting
Setting Range Remarks
15 5Hz 0 to 120Hz
0 to 3600 s When Pr. 21 = 0
16 0.5 s
0 to 360 s When Pr. 21 = 1
Pr.20
Pr.15
Pr.16
ON
ON
ON
JOG signal
Reverse rotation STR
Output frequency (Hz)
Jog frequency
setting range
Reverse
rotation
Tim
e
Forward
rotation
Forward rotation STF
Note: 1. In S-shaped acceleration/deceleration pattern A, the set time is a period of time required to reach
Pr. 3 "base frequency".
2. The acceleration time and deceleration time cannot be set separately for jog operation.
3. The value set in Pr. 15 "jog frequency" should be equal to or greater than the Pr. 13 "starting
frequency" setting.
4