8-9
Chapter 8 SXYX
2-3-2 Arm type with whipover cable, moving arm type, pole type
1) Remove the small screws (M4, 4 screws) fixing the X-axis wiring box cover,
and remove the cover. (Refer to Fig. 8-10.)
Remove the four M4 screws
Fig. 8-10
2) Fix the ring-tongue terminal of the ground wire to the ground terminal in the
X-axis wiring box.
An M4 small screw with spring washer and lock washer are attached to the
ground terminal. Arrange the parts in the order of the lock washer, ring-tongue
terminal and M4 small screw with spring washer, and then tighten. (Refer to
Fig. 8-11.)
M4 small screw with spring washer
Ring-tongue terminal
Lock washer
Fig. 8-11
3) Return the cover to the original position. Lead out the ground wire from the
user wiring outlet on the end face of the X-axis wiring box.