Yamaha 4-axis model Welding System User Manual


 
9-2
Chapter 9 MXYX
1-4 Installation methods
(Arm type, moving arm type, pole type, gantry type X-axis)
WARNING
Always use the designated bolt, and securely tighten it with the correct
torque. Failure to observe this could cause the robot position to deviate,
and could also lead to serious accidents.
1) Tap M8 coarse screw thread holes into the installation base where the robot is
to be installed.
Refer to the XY-X Series catalog for the hole positions.
2) Loosen the small screws (M5, 4 screws) fixing the X-axis wiring box. The
wiring box can be slid along the T slot when these screws are loosened. (Re-
fer to Fig. 9-2.)
Fig. 9-2
3) Remove the countersunk head screws fixing the X-axis stroke cover. (M4
countersunk head screw, 6 screws)
Fig. 9-3 MXY X-axis
!
CAUTION
The screws indicated with an asterisk (*) in the above drawing should be re-
moved from the wiring clearance after sliding the X-axis wiring box. Take care
not to damage the wires at this time. (Refer to Fig. 9-4.)
Fig. 9-4