Dell SCv2020 Tool Storage User Manual


 
NOTE: Do not install SAS HBAs from different vendors in the same server.
2. Install supported drivers for the HBAs and make sure that the HBAs have the latest supported
firmware installed.
3. Use the SAS cabling diagram to cable the host servers directly to the storage system.
NOTE: If deploying vSphere hosts, configure only one host at a time.
SAS Virtual Port Mode
To provide redundancy in SAS virtual port mode, the front-end ports on each storage controller must be
directly connected the server.
In SAS virtual port mode, a volume is active on only one storage controller, but it is visible to both storage
controllers. Asymmetric Logical Unit Access (ALUA) controls the path that a server uses to access a
volume.
If a storage controller becomes unavailable, the volume becomes active on the other storage controller.
The state of the paths on the available storage controller are set to Active/Optimized and the state of the
paths on the other storage controller are set to Standby. When the storage controller becomes available
again and the ports are rebalanced, the volume moves back to its preferred storage controller and the
ALUA states are updated.
If a SAS path becomes unavailable, the Active/Optimized volumes on that path become active on the
other storage controller. The state of the failed path for those volumes is set to Standby and the state of
the active path for those volumes is set to Active/Optimized.
NOTE: Failover in SAS virtual port mode occurs within a single fault domain. Therefore, a server
must have both connections in the same fault domain. For example, if a server is connected to SAS
port 2 on one storage controller, it must be connected to SAS port two on the other storage
controller. If a server is not cabled correctly when a storage controller or SAS path becomes
unavailable, access to the volume is lost.
Two Servers Connected to Dual 12 Gb 4–Port SAS Storage Controllers
A storage system with four 12 Gb front-end SAS ports on each storage controller can connect up to two
host servers, if each host server has two SAS HBAs with dual SAS ports.
About this task
In this configuration, there are four fault domains spread across both storage controllers. The storage
controllers are connected to each host server using four SAS connections.
If a storage controller becomes unavailable, all of the standby paths on the other storage controller
become active.
Steps
1. Connect fault domain 1 (shown in orange) to the host server 1.
a. Connect a SAS cable from storage controller 1: port 1 to host server 1.
b. Connect a SAS cable from storage controller 2: port 1 to host server 1.
2. Connect fault domain 2 (shown in blue) to the host server 1.
a. Connect a SAS cable from storage controller 1: port 2 to host server 1.
b. Connect a SAS cable from storage controller 2: port 2 to host server 1.
3. Connect fault domain 3 (shown in gray) to the host server 2.
a. Connect a SAS cable from storage controller 1: port 3 to host server 2.
56
Front-End Cabling