Dell SCv2020 Tool Storage User Manual


 
Steps
1. Connect the replication port on storage controller 1 to Ethernet switch 2.
2. Connect the replication port on storage controller 2 to Ethernet switch 2.
NOTE: The management port on each storage controller is connected to an Ethernet switch on
the management network.
Figure 53. Replication Ports Connected to an iSCSI Network
1. Ethernet switch 1 (Management network) 2. Ethernet switch 2 (iSCSI network)
3. Storage system 4. Storage controller 1
5. Storage controller 2
3. To configure the fault domain and ports, click the Configure Embedded iSCSI Ports link on the
Configuration Complete page of the Discover and Configure Uninitialized SCv2000 Series Storage
Centers wizard.
4. To configure replication, refer to the Dell Enterprise Manager Administrator’s Guide.
Related Links
Configure Embedded iSCSI Ports
Cabling the Management Port and Replication Port for iSCSI Replication
If replication is licensed and the Flex Port license is installed, both the management (MGMT) and
replication (REPL) ports can be used to replicate data to another Storage Center.
About this task
Connect the management port and replication port on each storage controller to an Ethernet switch
through which the Storage Center can perform replication.
Steps
1. Connect Flex Port Domain 1 (shown in orange) to the iSCSI network.
a. Connect the management port on storage controller 1 to the Ethernet switch.
b. Connect the management port on storage controller 2 to the Ethernet switch.
2. Connect iSCSI Embedded Domain 2 (shown in blue) to the iSCSI network.
a. Connect the replication port on storage controller 1 to the Ethernet switch.
b. Connect the replication port on storage controller 2 to the Ethernet switch.
Front-End Cabling
63