KEY FUNCTIONS
ETC00781(4) Series 100 e 02/2004
KEY FUNCTION OVERVIEW
Fig. 7-1: 100 Series Operating Function Matrix
Actual
Nominal
0..-10.-1
0 -1 CodE
0..-.1
t-AS.
t-AS CodE
PrES
SYS.- CodE
C.-On
C.CAL
Hold
PArA
tol.Auto
d.OFF
L-0
tPur
t90.1CodE
t90.2
OFS.1
OFS.2
End2End1
rES.
P.-N.o
S.-N.o
S.-
N.o.
PUMP
P.Ctl
On.-L
SIP. CodE
Id.No
232C
bAUd
LPb.Echo
bAUd
0 = 4800
1 = 2400
2 = 1200
3 = 600
LPb.
longitudinal-parity-byte-check
on/off
only with
Auto = 1
Serial-Interface-Parameters
Threshold of Limit-Outputs
Low = lower threshold
High = upper threshold
only with Option
"Serial Interface"
Automatic Zero-Level/Span Adjustment
Interval-Time (hrs.); 0 = off
Automatic Zero-Level Adjustment
Interval-Time (hrs.); 0 = off
Zero-Level Adjustment Channel 2
Zero-Level Adjustment Channel 1
Span Adjustment Channel 1
Span Adjustment Channel 2
----
----
5
4
3
2
6
7
8
9
1
Status
input
on/off
on/off
on/off
on/off
on/off
on/off
on/off
input
input
input
input
input
input
input
input
input
display
display
display
on/off/dis.
input
BINOS
100
BINOS
100 F
BINOS
100 M
BINOS
100 2M
HYDROS
100
OXYNOS
100
Programm - Version 5.1x
On Line
RS485-
RS232/
Echo
Baudrate
SYS.-PArA: System Parameters
Meaning
actual air-pressure (hPa)
correction of cross-sensitivity
calibrate cross-correction by span calibration
hold measure- and limit-outputs during a calibration
automatice calibration with a installed valve unit
tolerance check of calibration gases
display off, if no key pressed
"Live-Zero" for analoge measure outputs
purge-delay of gas supply (sec.)
user-code
t90-time channel 1
t90-time channel 2
concentration for 0(0,2) V resp. 0(4) mA at analog-output ch.1
concentration for 0(0,2) V resp. 0(4) mA at analog-output ch.2
concentration for 1 V resp. 20 mA at analog-output channel 1
concentration for 1 V resp. 20 mA at analog-output channel 2
reset of device; adjustment of fabrication-data
program version
serial number of device part 1
serial number of device part 2
pump status
pump controly number
Calibrate
Actual
Nominal
0..-20.-2
0 -2 CodE
0..-.2
Calibrate
Actual
Nominal
S..-1S.-1
S -1 CodE
S..-.1
Calibrate
Actual
Nominal
S..-2S.-2
S -2 CodE
S..-.2
Calibrate
Ch 1
Ch 1
L.-1HL.-1L
LI. CodE
L.-2L
Ch 2 Ch 2
L.-2H
0 1 2 3 4 5 6 7 8 9
10 11 12 13 14 15 16 17 18 19 20
21 22
t-A0.
t-A0 CodE
FUNCTION
ENTER
Name
PrES
C.-On
C.CAL
Hold
Auto
tol.
d.OFF
L-0
tPur
CodE
t90.1
t90.2
OFS.1
OFS.2
End1
End2
rES.
P.-No
S.-N.o
S.-N.o.
PUMP
P.Ctl
4 = 9600
5 = 19200
6 = 38400
CODE: factory setting “1”
Touch screen release:
DOWN, UP, ENTER, FUNCTION