Grizzly G0763 Planer User Manual


 
Model G0763 (Mfg. Since 8/13)
-23-
Figure 27. Resetting the Emergency STOP
button.
4. Fill the coolant tank with coolant (refer to
Coolant System on Page 37 for detailed
instructions).
5. If grinding wheel is mounted, make sure it is
properly mounted and wheel guard is prop-
erly secured (refer to Mounting/Removing
Wheel on Page 28 for detailed instructions).
Note: If grinding wheel is not mounted, it is
not necessary to mount it to complete Test
Run.
6. Turn master power switch ON—control panel
power lamp should light.
7. Twist Emergency STOP button clockwise
until it pops out (see Figure 27)—this resets
button so machine can start.
8. Make sure grinding wheel and guard are
safely above magnetic chuck but low enough
for coolant to flow onto chuck in a later step
without excessive splashing.
9. Press grinding motor ON button. Grinding
motor should start.
10. Press grinding motor OFF button. Grinding
motor should stop.
11. Make sure coolant nozzle is positioned close
to table and pointing to the left, then open
coolant valve.
12. Press coolant pump ON button. Coolant
should flow from coolant nozzle.
13. Press coolant pump OFF button and close
coolant valve. Coolant flow should stop.
14. Press Emergency STOP button.
15. WITHOUT resetting the STOP button, press
the grinding motor ON button. Machine should
not start.
—If the machine does start (with the
Emergency STOP button pushed in),
immediately disconnect power to the
machine. The Emergency STOP button
safety feature is not working correctly. This
safety feature must work properly before
proceeding with regular operations. Call
Tech Support for help.
16. Reset Emergency STOP button.
17. Rotate X- and Y-axis speed control knobs
on power feed unit all the way counterclock-
wise—this prevents unexpected table move-
ment when power is enabled to unit.
18. Turn power feed unit ON.
19. Rotate X-axis mode selector switch to the
right (pointing at “table” symbol).
Note: In the next steps, keep your hand over
the speed control knobs so you can quickly
stop table movement if necessary.
20. Slowly rotate X-axis speed control knob until
tables begins to move. Table should travel
side-to-side automatically.
21. Rotate Y-axis mode selector switch to the
right (pointing at “table” symbol).
22. Slowly rotate Y-axis speed control knob until
tables begins to move. Table should move
when table completes one X-axis side-to-side
cycle.
23. Rotate X- and Y-axis speed control knobs all
the way counterclockwise to stop table move-
ment.
24. Rotate X- and Y-axis mode selector switches
to point at “hand” symbol to avoid unexpected
start up in the future.
25. Turn power feed unit OFF.
Congratulations! The Test Run is complete. Press
the Emergency STOP button in and turn the mas-
ter power switch OFF.