Lincoln Electric SVM175-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-98 F-98
RANGER 305D
This is the typical DC open circuit out-
put voltage generated from a properly
operating machine. Note that each
vertical division represents 50 volts
and that each horizontal division rep-
resents 5 milliseconds in time.
NOTE: Scope probes are connected
at weld output terminals.
SCOPE SETTINGS
Volts/Div.....................50V/Div.
Horizontal Sweep .....5 ms/Div.
Coupling.............................DC
Trigger.........................Internal
NORMAL OPEN CIRCUIT VOLTAGE WAVEFORM (STICK)
MAX CONTROL POT - HIGH IDLE - NO LOAD
0 volts
50V 5ms
CH1