Sterling Plumbing 882 00276.00 Welder User Manual


 
Digital Dosing Units
23
Signal Converter with DC Power Supply
This module requires a separate 24 VDC power supply.
Vendor: Phoenix Contact
Order Designation: MCR-FL-C-UI-2UI-DCI-NC
Supply Voltage: 20 to 30V DC
Input 4-20 mA, 0-10V (Quantity: 1)
Output 0-20 mA, 0-10V (Quantity: 2)
24 VDC Mini Power Supply
A Phoenix Contact power supply for the Phoenix Contact signal conditioner listed above.
Vendor: Phoenix Contact
Order Designation: MINI-PS-100-240AC/24DC/1
Please note that the data given here has been taken from Phoenix Contact's online catalog.
For comprehensive information and data, please refer to the user documentation at
http://www.download.phoenixcontact.com.
3.2 Initial Operation
The control system is factory-programmed. Nevertheless, specific values need to be
predefined or checked prior to operation (basic parameter settings). The input values will be
saved and will still be available if the unit is switched off, or a power failure occurs. Please
refer to Appendix B for these values. Extrusion operations require a “span factor” to be
entered into the basic settings. Please refer to Appendix B.
Prior to putting your new Digital Dosing Additive Feeder on-line:
You must enter a recipe and calibrate the feeder.
Recipe parameters are different for Injection Molding, Extrusion - Constant,
and Extrusion - Proportional operation. See each individual section for
details.
The calibration method is the same for all processes.
Once the unit is online, recipes can be saved for later recall (10 maximum).