Installing Different Types of Dosing Discs
Dosing discs of the same type, and thickness (72 pocket), may be exchanged for each other
without any problems. If dosing discs with a different compartment number or thickness are
installed, this has to be entered in the control system!
DD Discs
Disc Calibration
Number
Number of
pockets
DD 30-030672 1.75 72
DD 30-051040 5.00 40
DD 30-051725 8.00 25
DD 30-051818 15.00 18
1. Enter the (preliminary) calibration value of the newly installed dosing disc
2. Execute “calibration” to determine the final calibration value.
5.5 Removing / Replacing the Wiper in the DT Dosing Station
1. Empty the dosing station.
2. Open the profile clamp (C) of the
dosing container.
3. Remove the profile clamp (C)
4. Remove the dosing container (B)
along with the dosing hopper (A).
5. Loosen the 3 plastic screws on
the wiper.
6. Remove the wiper and holding
plate.
7. Install the new wiper along with
the holding plate.