Digital Dosing Units
39
• This sample should be returned to the material hopper without weighing.
This sample is used only to ensure that all disc pockets are completely filled.
• Replace container in calibration box (or under material outlet tube)
Step 3:
• Press
to take a sample for weighing.
• The disc will rotate one full revolution. After the disc has stopped rotating, a
number in the format “xx.xx” will appear on the screen along with a flashing
and “g.”
Step 4:
• Enter the weight, in grams using the Arrow Keys
• Empty and replace weighing container in calibration box (or under material
outlet tube)
Step 5:
• Repeat steps 3 and 4 four (4) more times.
• Notice that the displayed calibration weight may change after each sample
weight is entered.
• The value is an average of all the weights entered. No calculations are
required. It can happen that the calculated speed is either too high or low
causing alarm A0009. Check the recipe and settings and modify if
necessary.