Brother BAS-300G Welding System User Manual


 
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
37
BAS-300G, BAS-311G, BAS-326G
6-5. Using the production counter
<Setting the counter value>
1
TEST indicator and SPEED indicator illuminate
COUNTER indicator flashes
While pressing the TEST key, press the key.
The counter value that was previously set will appear
as a 7-digit number in the PROGRAM No. display and
the menu display.
2
Press the or key to set the counter value.
The counter value can be set to between "000" "0000"
and "999" "9999".
If you press the RESET key during setting mode, the
value will become "000" "0000".
3
Ending setting mode
TEST indicator switches off
Press the TEST key.
The counter value will be memorized.
<Production counter operation>
If you press the SELECT key (1) to select the counter display menu when memory switch no. 300 is set to "ON", the SPEED
and COUNTER indicators will illuminate and the production counter will appear in the menu display (2).
1. Each time the sewing of a single article is completed,
the value shown in the menu display (2) is increased by
1.
2. While the
key (3) is being pressed, the first three
digits will appear in the PROGRAM No. display (4) so
that the total number of digits displayed will be seven.
3. If you press the RESET key (5) for 2 seconds or more,
the counter value will be reset to [0000].
Temporary display function
You can display the production counter temporarily while
the lower thread counter is being displayed.
When the SPEED indicator is illuminated, hold down the
TEST key (6) and then press the RESET key (5) to display
the production counter in the menu display (2).
Press the TEST key (6) or the SELECT key (1) to switch the
menu back to the normal menu display.
* You can start sewing while the temporary display still
appears.
4465Q4464Q
4466Q