10. STANDARD ADJUSTMENTS
BAS-300G, BAS-311G, BAS-326G
63
10-12. Adjusting the thread wiper
1. Loosen the two screws (3) and shift the entire solenoid setting plate (4) up or down to adjust so that the thread wiper (2) is
15 mm in front of the needle center when the plunger (1) of the thread wiper solenoid is driven to the full stroke.
2. Loosen the screw (5) and adjust the position of the thread wiper (2) so that the distance from the thread wiper to the tip of
the needle is approximately 2 mm and the tip of the thread wiper (2) is approximately 3 mm from the center of the needle
when the thread wiper (2) passes below the needle during operation.
Note: Check that the thread wiper (2) does not touch the finger guard.
10-13. Presser foot installation position
Install the presser foot (1) with the screw (2) so that the
distance from the bottom of the presser foot to the top of the
needle plate is 22 mm when the sewing machine is stopped
and the presser foot (1) is raised.
Approx. 2mm
Approx. 3mm
5009Q5008Q5007Q
5031Q