Brother BAS-300G Welding System User Manual


 
6. USING THE OPERATION PANEL (ADVANCED OPERATIONS)
41
BAS-300G, BAS-311G, BAS-326G
<Setting method>
1. Press the
or key (1) to select the user program
number that you would like to use.
If the user program number is flashing, depress the
foot switch to move the feed mechanism to the home
position. After this, it is not necessary to detect the
home position until the next time the power is turned
off and back on, even if you change the user program
number.
User programs U1 to U10 can be selected directly
using function keys F1 to F4 (2). (Refer to "6-9. Direct
selection".)
2. Check that the needle drop position is correct, and then
start sewing. (Refer to "5-6 Checking the sewing
pattern".)
If you press the SELECT key (3), you can check the settings for the displayed user program (such as X-scale, Y-scale and
sewing speed).
<Clearing method>
1
TEST indicator illuminates, MENU indicator flashes
While pressing the TEST key, press the SELECT key
Switch to user program recording mode. Check that
the menu indicators are flashing.
The user program number will appear in the
PROGRAM No. display, and the program number will
appear in the menu display.
Press the
or key (1) to select the user program
number that you would like to clear.
2
Press the RESET key.
The buzzer will sound and the user program with the
number selected will be cleared.
NOTE:
If a cleared user program has been stored as part of
a cycle program, the step that involves that user
program will become blank. The cycle program itself
will not be cleared.
Clearing all user programs
Press and hold the RESET key for 2 seconds or more.
The buzzer will sound and all user programs will be
cleared.
NOTE:
If any cycle programs have been memorized, all of
the memorized cycle programs will also be cleared.
4970Q