10. STANDARD ADJUSTMENTS
BAS-300G, BAS-311G, BAS-326G
62
10-11-1. Installing the feed plate
1
MENU indicator switches off
THREAD/CLAMP indicator illuminates
While pressing the THREAD/CLAMP key, turn on the power
switch.
* Keep pressing the THREAD/CLAMP key until the model
name is displayed and the buzzer beeps once.
"CLMP" will appear in the menu display.
2
Depress the foot switch to the 2nd step.
(If using a two-pedal foot switch, lower the work clamp before
depressing the start switch.)
After the home position is detected and the work clamp drops, the
feed mechanism will move to the feed plate installation position and
then the work clamp will rise.
3
Use a 2 mm diameter pin to align the holes in the X feed bracket (1) and the needle plate (2) with the two holes in the
feed plate (3), and then tighten the two bolts (4).
NOTE: Install the feed plate so that the surface with the index mark is facing upward.
4
End feed plate installation mode
Turn off the power.
4421Q
All indicators switch off
2nd step
5005Q
4441Q
2373B
Index