ACCESSORIES
C-4
K1450-“L” - Extension cables are available in lengths
“L” of 12, 16 or 25 ft (3.6, 4.9 or 7.6 m) to match the
control to Feeder cable length used.
K1558-1 - Remote Switch Interface Module, can be
used with the DH-10, using a G3041-2 (or higher)
Control Board. The module provides for user interface
connection of an external switch (flow switch, etc)
which must be closed to enable the feeder welding
operation. Also, the module provides for interface con-
nection of external equipment (fume extractor, etc.) To
the module’s isolated relay contacts which actuate
when the feeder welding gas solenoid is activated
(representing welding operation in process).
When used with the DH-10, the module provides
these input and output switch function connections
independently for each head operation.
This module is necessary when using the K1536-1
waterflow sense kit with the DH-10.
K683-1 DUAL PROCEDURE SWITCH
(One per gun) - Requires K686-2 Adapter for DH-10.
Kit includes gun switch, and mountings for Lincoln
Innershield and Magnum guns, with 15 ft (4.5 m) con-
trol cable and 3-pin plug. K686-2 Adapter permits
3-pin plug and 5-pin gun trigger plug to be connected
to DH-10 5-pin Trigger/Dual Procedure receptacle.
K683-3 DUAL PROCEDURE SWITCH
(One per gun) Kit includes gun switch, and mountings
for Lincoln Innershield and Magnum guns, with 15 ft
(4.5 m) control cable and 5-pin plug with two leads to
connect to gun trigger.
SPINDLE ADAPTERS
K162H - (Not required for DH-10 Bench Models)
Spindle for boom mounting Readi-Reels and 2 in.
(51 mm) I.D. spools with 60 lb (27.2 kg) capacity.
User mounted to appropriately prepared boom frame-
work. Includes an easily adjustable friction brake for
control of overrun.
When a 2 in. (51 mm) spindle is used with Readi-
Reels or coils not on 12 in. (305 mm) O.D. spools, an
adapter is required:
Coil Adapters
K1504-1 - Permits 50 lb to 60 lb (22.7-27.2 kg) Coils
to be mounted on 2 in. (51 mm) O.D. spindles.
K435 - Permits 14 lb (6 kg) Innershield coils to be
mounted on 2 in. (51 mm) O.D. spindles.
K468 - Permits 8 in. (203 mm) O.D. spools to be
mounted on 2 in. (51 mm) O.D. spindles.
INPUT CABLE ASSEMBLIES
(One required per DH-10 Control Box.)
K1501 (Control Cable Only) - Consists of a 9-conduc-
tor control cable with a 14-pin control cable plug, with-
out electrode cable, and is available in lengths of 10 ft
(3 m), 17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m), 50 ft
(15 m) and 100 ft (30 m).
K1502 - Consists of a 9-conductor control cable with a
14-pin plug and a 3/0 (85 mm
2
) electrode cable with
stud terminal. It is rated at 600 amps, 60% duty cycle
and is available in lengths of 10 ft (3 mm), 17 ft (5 m),
25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m) and 100 ft
(30 m) is also available with a 4/0 (107 mm
2
) elec-
trode cable.
K1503 - Consists of a 9-conductor control cable with a
14-pin plug and 2/0 (67 mm
2
) electrode cable with
Twist-Mate™ connector. It is rated at 500 amps, 60%
duty cycle and is available in lengths of 10 ft (3 m),
17 ft (5 m), 25 ft (7.6 m), 33 ft (10 m) and 50 ft (15 m)
and 100 ft (30 m) is also available with a 3/0
(85 mm
2
) electrode cable.
K1520-1 115V/42V TRANSFORMER KIT
Required to use DH-10 with Lincoln Power Sources
without 42VAC auxiliary and a 14-pin connector
receptacle. These power sources include the DC-250,
DC-600, DC-1000 and Pulse Power 500. Also can be
used with older DC-400 models.
K590-4 WATER CONNECTION KIT
(One per gun) Includes water cooled gun tube fittings
and self-sealing outlet and inlet quick-connectors for
mounting into the DH wire drive connection box.
K659-1 GAS GUARD REGULATOR
(One per gun) Adjustable flow regulator with remov-
able adjustor key for CO
2
and Argon blend gases.
Mounts onto wire drive gas inlet, and reduces gas
waste and arc start “blow” by reducing surge caused
by excess pressure in supply hose.
K1449-1 DUAL PROCEDURE REMOTE CONTROL
(One per DH-10 Control Box) Includes a remote con-
trol box with a 16 ft (5 m) length control cable with
4-pin plug for the mating receptacle on the bottom of
the DH-10 control box. The remote control box con-
tains a procedure selector switch and 2 rotating knob
encoders, one controls arc voltage and the other con-
trols wire feed speed, which function the same as
comparable controls on the DH-10 front panel, when
the remote is connected and selected by the DH-10
Procedure Key.
DH-10