Lincoln Electric SVM 110-A Welder User Manual


 
MUFFLER RELOCATION
Shut off the machine and allow the muffler to cool
before touching the muffler.
The RANGER 9 is shipped with the exhaust coming
out on the left side. It can be changed to the right side
by removing two screws that hold the exhaust port
cover in place and installing the cover on the opposite
side.
NOTE: Operating the RANGER 9 without the cover in
place will not increase the machine output and
will result in a higher noise level.
SPARK ARRESTER
Gasoline engine mufflers may emit sparks when the
engine is running. Some federal, state, or local laws
require spark arresters in locations where unarrested
sparks could present a fire hazard.
Standard mufflers and deflectors (like the ones includ-
ed with the RANGER 9) do not act as spark arresters.
When local laws require it, a spark arrester must be
installed on the machine and properly maintained. An
optional spark arrester kit (K894-1) is available for your
RANGER 9. See the Accessories section of this man-
ual for more information.
An incorrect spark arrester may lead to damage to the
engine or reduce performance.
ELECTRICAL OUTPUT
CONNECTIONS
See Figure A.1 for the location of the output range
selector, fine output control, polarity switch, control at
welder/remote control switch, welding terminals
always on/remotely controlled switch 115 and 230 volt
receptacles, weld output terminals, and ground stud.
INSTALLATION
A-5 A-5
RANGER 9 RANGER 9
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
AC
DC+
DC-
LINCOLN
ELECTRIC
RANGER 9
WARNING
RANGE
175
125
90
70
50
16 to 25
225 AC
210 DC
1
2
3
4
5
10 max
9
8
7
6
5
2
1
7
6
CHOKE
AUTO
HIGH
IDLER
START
RUN
STOP
8
9
43
FIGURE A.1 - RANGER 9 OUTPUT CONNECTIONS
1. OUTPUT RANGE SELECTOR
2. FINE OUTPUT CONTROL
3. CONTROL AT WELDER/REMOTE CONTROL SWITCH
4. WELDING TERMINALS SWITCH
5. POLARITY SWITCH
6. 115/230 VOLT, 50 AMP RECEPTACLE
7. 115 VOLT, 20 AMP RECEPTACLES (2)
8. WELD OUTPUT TERMINALS (2)
9. GROUND STUD
WARNING
CAUTION