Mitsubishi Electronics MDS-D-SVJ3 Engraver User Manual


 
5 - 8
5 Dedicated Options
MITSUBISHI CNC
System configuration
1. MDS-D-SVJ3 Series have no battery voltage drop warning signal input. Connect to CN9 of MDS-D/
DH/DM Series servo drive unit.
2. 24V power for DO output must always be turned ON before the NC power input.
3. Spindle drive unit has no battery voltage drop warning function. Wiring to CN9 of drive unit must be
always connected to servo drive unit.
4. The total length of battery cable (from the battery unit to the last connected drive unit) must be 3m
or less.
.
.
%0
$6$ $6$
DOCOM
DO(ALM)
LG
+5V
LG
BT
$#6 $#6
8
4)
&)
&)
&)
&)
&)
(MDS-D/DH-V1) (MDS-D/DH-V2) (MDS-D/DH-SP) (MDS-D/DH-CV)
MDS-BTBOX-36
(MDS-D-SVJ3) (MDS-D-SVJ3)
I/O power
Battery box
1-axis servo
drive unit
Spindle
drive unit
Power supply
unit
2-axis servo
drive unit
From NC
Connect the +5V
power and DO
output with one
of servo drive
units.
Servo
drive unit
Servo
drive unit
When connecting a battery box to MDS-D-SVJ3,
connect to the connector "BAT". (It is the same
as that for the cell battery connection. )
CAUTION