Mitsubishi Electronics MDS-D-SVJ3 Engraver User Manual


 
6 - 3
MDS-D-SVJ3/SPJ3 Series Specifications Manual
6-1 Selection of wire
(3) 600V bridge polyethylene insulated wire (IC) 105 °C product
(Example according to JEAC8001)
Terminal name
Unit type
CNP1
(L1, L2, L3, )
CNP2
(L11, L21)
CNP3
(U, V, W, )
CNP2
(P,C)
Magnetic
brake
mm
2
AWG
mm
2
AWG
mm
2
AWG
mm
2
AWG
mm
2
AWG
Spindle
drive
unit
MDS-D-SPJ3-075NA 214
1.25 16
214
214
--- ---
MDS-D-SPJ3-22NA 214 214
MDS-D-SPJ3-37NA 214 214
MDS-D-SPJ3-55NA 214 3.512
MDS-D-SPJ3-75NA 3.5 12 3.5 10
3.5 12
MDS-D-SPJ3-110NA 5.5 10 5.5 10
Servo
drive
unit
MDS-D-SVJ3-03NA 214
1.25 16
214
2 141.2516
MDS-D-SVJ3-04NA 214 214
MDS-D-SVJ3-07NA 214 214
MDS-D-SVJ3-10NA 214 214
MDS-D-SVJ3-20NA 214 214
MDS-D-SVJ3-35NA 214 3.512
1. Selection conditions follow IEC/EN60204-1, UL508C, JEAC8001.
- Ambient temperature is maximum 40°C.
- Cable installed on walls without ducts or conduits.
To use the wire under conditions other than above, check the standards you are supposed to
follow.
2. The maximum wiring length to the motor is 30m.
If the wiring distance between the drive unit and motor is 20m or longer, use a thick wire so that the
cable voltage drop is 2% or less.
3. Always wire the grounding wire.
CAUTION