Appendix 6 Instruction Manual for Compliance with UL/c-UL
MITSUBISHI CNC
Appendix 6 - 6
(3) Servo Drive Unit (MDS-D/DH/DM-V1/V2/V3/D-SVJ3)
TE2 (L+, L-)
Wire size depends on the Power Supply Unit (MDS-D/DH-CV Series).
TE3 or CNP2 (L11, L21)
TE1 (U, V, W, )
CNP1 (L1, L2, L3), CNP3 (U, V, W) and
(Note) 75 °C:Grade heat-resistant polyvinyl chloride insulated wires (HIV).
Use copper wire only.
Above listed wire are for use in the electric cabinet on machine or equipment.
(4) AC Reactor (D/DH-AL)
Input/Output (L11, L12, L13, L21, L22, L23)
The wire connected with AC Reactor becomes same size as TE1 of the selected Power supply unit.
Unit Type
MDS-D-V1(#)- 160W, 320 320W --- ---
MDS-DH-V1(#)- 160, 160W 200 --- ---
MDS-D-SVJ3(#)- --- --- 10 to 35(##)
10(##)
20(##)
Terminal
Screw
Size
TE2 (L+, L-)
Torque [lb in/ N m]
M6 M6 --- ---
35.4/4.0 <- --- ---
TE3 (L11, L21)
Torque [lb in/ N m]
M4 M4 --- ---
10.6/1.2 <- --- ---
TE1 (L1, L2, L3, )
Torque [lb in/ N m]
M5 M8 --- ---
17.7/2.0 53.1/6.0 --- ---
CNP1 (L1,L2,L3,N,P1,P2) and
CNP3 (U,V,W))
Torque [lb in/ N m]
--- --- --- ---
--- --- 5.3/0.6 ---
Unit Type
MDS-D/DH/DM-V1(#)/V2(#)/V3(#)- 10 to 320W ---
MDS-D-SVJ3(#)- --- 03(##) to 35(##)
Wire Size (AWG)
/Temp Rating
Note 1
#14/75°C #14/60 or 75°C
Crimping Terminals Type R2-4 ---
Crimping Tools Type YHT-2210 ---
Unit Type
MDS-D-V1(#)- 20 to 80 160
MDS-DH-V1(#)- 10 to 80 80W
Wire Size (AWG)
/Temp Rating
Note 1
#14
/75°C
#10
/75°C
Unit Type
MDS-D-V1(#)- --- 160W 320 320W
MDS-DH-V1(#)- 160 160W --- 200
Wire Size (AWG)
/Temp Rating
Note 1
#10
/75°C
#8
/75°C
#6
/75°C
#4
/75°C
Crimping Terminals Type R5.5-5 R8-5 R14-5 R22-8
Crimping Tools Type YHT-2210 YPT-60-21 <- <-
Unit Type MDS-D-SVJ3(#)- 03(##) to 20(##) 35(##)
Wire Size (AWG)
/Temp Rating
Note 1
#14
/60 or 75°C
#12
/60 or 75°C
Type
D-AL- 7.5K, 11K 18.5K to 45K 55K
DH-AL- 7.5K, 11K 18.5K to 75K ---
Terminal
Screw
Size
L11, L12, L13, L21, L22, L23 M5 M6 M10
Torque [lb in/ N m] 17.7/2.0 35.4/4.0 97.3/11.0