Nortel Networks 411-2021-111 Welding System User Manual


 
DualMode Metrocell Cell Site Specifications
7-5
DMS-MTX DualMode Metrocell Cell Site Description
Earthquake Meet earthquake requirements of Zone 1
and Zone 2 as defined by Bellcore
TR-NWT-000063
Fixed equipment anchorage.
Thermal dissipation for Metrocell RF Frame:
Regulatory
Electromagnetic Emissions
Cell site equipment complies with the following Regulatory Specification:
FCC part 22 for 800 MHz frequency
FCC part 15 Class B for cell site with Universal CE Frame and Metro RF
Frame (except for the ICRM, CSM, HSMO and ACU shelves located on
the Universal CE Frame)
DOC RSS-128 Issue 1.0 Dual Mode Capability in Canada
|
Radiated Emissions
Cell site equipment complies with the following Regulatory Specification:
FCC Part 22 for 800 MHz frequency
FCC Part 15 Class B for cell site with Universal CE Frame and Metro RF
Frame (except for the ICRM, CSM, HSMO and ACU shelves located on
the Universal CE Frame)
Bell Canada Design Standard TAD 8465 of Bellcore TR-NWT-001089 in
10 kHz to 30 MHz and 1 GHz to 10 GHz range for radiated emission
Telecom Compliance
Cell site equipment complies with the following Regulatory Specification:
CS03, Issue 7, Part 2 (Table 1: Digital Interface Requirement, Type IV)
FCC Part 68 (TSB31, Table 4.5-2: Test Requirement Matrix)
Component Dissipation per
unit
Maximum
number of units
Total
dissipation
TRU 27 W 24 648 W
PA 89 W 24 2136 W
Combiner (-4.5 dB) 21 W 24 504 W
Duplexer (-0.7 dB) 9.3 W 3 28 W
Total 3.3 KW