Quinny 65040-AB Air Compressor User Manual


 
Section VIII - Power$ync II
Operation
52 Quincy Compressor
®
- QSD
Press F3 at the Compressor Hourmeter Menu to access
three additional menus used to reset maintenance
hourmeters after service has been performed. To scroll
through these three reset menus, use the UP and DOWN
arrow keys.
RESET HOURMETER MENU 1
RESET FLUID FILTER HOURS PRESS F1
RESET FLUID HOURS PRESS F2
UP FOR NEXT MENU/DOWN FOR PREVIOUS MENU
Press F1 to reset the fluid filter hourmeter after
replacement.
A confirmation message will be displayed before the
hourmeter is actually reset.
PRESS F1 TO RESET FLUID FILTER HOURS
PRESS ENTER TO RETURN
If this is the correct hourmeter to reset, press F1
again. If this is not the hourmeter that needs to be
reset, press ENTER to return to the previous menu.
After pressing F1, another message confirms that the
hourmeter has been reset.
FLUID FILTER HOURS RESET TO 0
PRESS ENTER TO RETURN
Press ENTER to return to the Reset Hourmeter
Menu 1.
From the Reset Hourmeter Menu 1, press F2 to reset the
fluid hourmeter. A confirmation message will be
displayed before the hourmeter is actually reset.
PRESS F1 TO RESET FLUID HOURS
PRESS ENTER TO RETURN
If this is the correct hourmeter to reset, press F1
again. If this is not the hourmeter that needs to be
reset, press ENTER to return to the previous menu.
FLUID HOURS RESET TO 0
PRESS ENTER TO RETURN
Press ENTER to return to the Reset Hourmeter
Menu 1.
RESET HOURMETER MENU 2
RESET LINE FILTER HOURS PRESS F1
RESET INTAKE FILTER HOURS PRESS F2
UP FOR NEXT MENU/DOWN FOR PREVIOUS MENU
From the Reset Hourmeter Menu 2, press F1 to
reset the line filter hourmeter. A confirmation
message will be displayed before the hourmeter is
actually reset.
From the Reset Hourmeter Menu 2, press F2 to reset the
inlet air filter hourmeter.
PRESS F1 TO RESET AIR FILTER HOURS
PRESS ENTER TO RETURN
If this is the correct hourmeter to reset, press F1
again. If this is not the hourmeter that needs to be
reset, press ENTER to return to the previous menu.
AIR FILTER HOURS RESET TO 0
PRESS ENTER TO RETURN
Press ENTER to return to the Reset Hourmeter
Menu 2.
COMPRESSOR MAINTENANCE MENU 1
MAINTENANCE HOURMETERS PRESS F1
TIME AND DATE PRESS F2
UP FOR NEXT MENU/DOWN FOR PREVIOUS MENU
To view or set time, date, and day of the week,
press F2. To scroll to another Maintenance Menu,
use the UP and DOWN arrow keys. To return to
the previous display, press ENTER.