Quinny 65040-AB Air Compressor User Manual


 
Section VIII - Power$ync II
Operation
Quincy Compressor
®
- QSD 65
STG 1 OUT TEMP______ STG 2 IN TEMP______
COMPRESSOR HAS TIMED OUT AND SHUT DOWN
WILL NOT RESTART AUTOMATICALLY
COMPRESSOR NOT IN SCHEDULED SEQUENCE
When compressors are running in Network Mode,
individual compressors can be scheduled out. If
a particular compressor ID is left out of a sequence
for a particular schedule, the network will consider
that compressor out of service. This feature can
be used to ensure that only certain machines run
at certain times of the day. A network of three
machines, ABC for example, can schedule a
sequence, BC for example, that leaves one of the
machines completely out. Machines that are not
in the scheduled sequence will not be turned on
during that schedule, regardless of system demand.
If there is a possibility that the system demand
might require all machines, do not leave any
machines out of any sequences.
NOTICE!
THE STAGE 1 BLOWDOWN MUFFLER MAY BE
BLOCKED PLEASE CHECK FOR OPERATION
COULD CAUSE OVER-PRESSURE SHUTDOWN!
NOTICE!
THE STAGE 2 BLOWDOWN MUFFLER MAY BE
BLOCKED PLEASE CHECK FOR OPERATION
COULD CAUSE OVER-PRESSURE SHUTDOWN!
These two messages are warning indicators that
the blowdown passages may be blocked or
degrading. These will trip if the pressure during
blowdown fails to reach 5 psig during an unloaded
condition. This is an important message to see;
the LED indicator for STAGE 2 DISCHARGE
PRESSURE or HIGH INTERSTAGE PRESSURE
will blink when this condition is detected. If this is
allowed to continue, degradation of the
compressor is likely.