Wagner SprayTech GM300AC Paint Sprayer User Manual


 
24
GM 3000AC
"?
B 00036
OPERATING MANUAL
EDITION 05/2007
PART NO. DOC364831
5.3 START-UP
Trigger safety catch in on
(safe) position
Air
Air
Material
Material
5.3.1 GENERAL RULES FOR MAKING ADJUSTMENTS TO THE SPRAY GUN
See safety regulations in chapter 2.
CAUTION
Cleaning agent in the air duct!
Functional faults caused by swollen seals
Always point the spray gun down when cleaning.
Ensure that neither paint nor cleaning agent enters the air duct.
SIHI_0005_GB
SIHI_0065_GB
WARNING
Unintentional putting into operation!
Risk of injury
Before all work on the unit, in the event of work interruptions and
functional faults:
Switch off the energy/compressed air supply.
Relieve the pressure from the spray gun and unit.
Secure the spray gun against actuation.
By functional faults: Identify and correct the problem, proceed
as described in chap„Trouble shooting“.