5.3.2 PREPARATION
1. Secure the spraygun.
2. Connect material hose to spray gun and to pump.
3. Connect air hose to spray gun and to oil-free, dry air supply with regulator.
4. Insert suitable gun fi lter.
5. Tighten the complete gun handle/ swivel assembly.
6. Place the nozzle into the nozzle seal. Fit the aircap over the nozzle, ensuring that the
location fl ats (X) are in line. Fit the aircap nut with nozzle guard and tighten by hand.
Note:
The pin in the housing is to adjust the spray jet in the horizontal or vertical position.
7. Visually check the permissible pressures for all the system components.
8. Make sure that the spraying unit and all other conductive parts within the work area
are earthed
9. Set material pressure approx. 100 bar; 10 MPa; 1450 psi and use a suitable medium
(solvent or water) to check that connections do not leak.
Note:
Pull the trigger and then release, checking that the gun closes cleany.
10. Relieve spray gun and unit pressure and secure the spraygun.