DSM250 User’s Manual
Page 178 Revision 1.4.16a
change the value to the desired tank capacity value, and finally, press the Accept key to confirm your
selection.
Figure 202 – Configuring the Tank Capacity
After you have pressed the Accept key, a confirmation screen will appear that warns you that the
fluid remaining measurement will change as a result of this change. Press the Accept key to accept
the change and store the new tank capacity value within the TLM100, or Press the Cancel Key to
cancel the change and leave the old tank capacity programmed into the TLM100.
Figure 203 – Tank Capacity Change Confirmation Screen
6.24.4 Tank Levels Calibration
In order for the TLM100 to indicate an accurate tank level, it must know the geometry of the tank.
There are two methods of calibrating the tank level sender:
• Custom Calibration – use for non-rectangular tanks (also, most accurate in any case, but
requires more effort)
• Rectangular Tank – By inputting some dimensions of a rectangular tank, the TLM100 is able to
interpolate the volume of liquid from the distance to the surface.