DSM250 User’s Manual
Page 48 Revision 1.4.16a
Figure 34 – Airmar Transducer Advanced Configuration Screen
6.1.2 Device Instance
This entry allows you to program the NMEA 2000 device instance for the unit. You usually will not
need to modify the default value of “0” unless you have multiple units on the network.
6.1.3 Installation Description
This entry allows you to modify the NMEA 2000 installation description text strings. You can enter
any information you like here, such as the date the unit was installed, or the location in which it was
installed, for later reference. Tools such as Maretron N2KAnalyzer allow you to view these values
later. See section 3.3.4 for details on how to enter a textual value.
6.1.4 NMEA2000 PGN Enable/Disable
The transducer transmits several different NMEA2000 PGN’s which can be turned on or turned off by
the DSM250 display. Pressing the Enter key with “NMEA2000 PGN Enable/Disable…” menu item
selected causes the DSM250 to display the NMEA2000 PGN Enable/Disable screen.
You can enable or disable the transmission of the these messages, or set the frequency of
transmission of the message by pressing the Enter key ( ) on the message to be configured.
Options are:
Off – The message will not be transmitted
On – The message will be transmitted at its default NMEA 2000
®
rate.
Select the required option using the Scroll Up and Scroll Down keys followed by the Enter key.
6.1.5 Clear Speed Calibration
The Clear Speed Calibration configuration parameter shows you the currently used correction
factor. All measured STW readings are multiplied by this number before being transmitted over the
NMEA 2000
®
network. You can remove the correction factor by pressing the Enter key ( ) with the
“Clear Speed Calibration:” menu item selected. And then choose “Clear” using Scroll Up ( ) or
Scroll Down ( ) keys followed by the Enter key ( ). This changes the correction factor back to 1