Lincoln Electric SP-250 Welding System User Manual


 
B-6
OPERATION
B-6
ARROW KEY OPERATION WHEN USED WITH
PROCESS WIRE/GAS KEY:
See Table B.1.
Left Arrow Keys: Press to set Wire Type. Pressing the
UP and DOWN arrow keys changes the Wire Type dis-
played.
Center Arrow Keys: Press to set Wire Diameter.
Press the UP ( ) arrow key to increase the wire diam-
eter displayed. Press the DOWN ( ) arrow key to
decrease the wire diameter displayed.
Right Arrow Keys: Press to select Welding Gas.
Pressing the UP and DOWN arrow keys changes the
Welding Gas displayed.
The following 16 processes are programmed into the
SP-250:
Wire Type Wire Diameter Welding Gas
Solid Steel .025 (0.6mm) CO2
Solid Steel .025 (0.6mm) ArCO2
Solid Steel .030 (0.8mm) CO2
Solid Steel .030 (0.8mm) ArCO2
Solid Steel .035 (0.9mm) CO2
Solid Steel 035 (0.9mm) ArCO2
Solid Steel .035 (0.9mm) ArOxy
Solid Steel .045 (1.2mm) CO2
Solid Steel .045 (1.2mm) ArCO2
Stainless .035 (0.9mm) ArOxy
Stainless 035 (0.9mm) HeArCo2
Aluminum (5356) 3/64 (1.2mm) Argon
Outershield .045 (1.2mm) CO2
Outershield .045 (1.2mm) ArCO2
Innershield .035 (0.9mm) None
Innershield .045 (1.2mm) None
IDEALARC SP-250
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TABLE B.1 - Arrow Key Functions.