Lincoln Electric SP-250 Welding System User Manual


 
F-35
TROUBLESHOOTING & REPAIR
F-35
IDEALARC SP-250
This is NOT the typical DC output voltage
waveform. The output capacitors are not
functioning. Note the lack of “filtering” in the
output waveform. The output capacitor
bank was disconnected. Each vertical divi-
sion represents 20 volts and each horizontal
division represents 5 milliseconds in time.
Note: Scope probes connected at machine
output terminals: (+) probe to electrode, (-)
probe to work.
Volts/Div . . . . . . . . . . . . . . . . .20 V/Div.
Horizontal Sweep . . . . . . . . . .5 ms/Div.
Coupling . . . . . . . . . . . . . . . . . . . . .DC.
Trigger . . . . . . . . . . . . . . . . . . .Internal.
SCOPE SETTINGS
ABNORMAL OPEN CIRCUIT VOLTAGE
OUTPUT CAPACITOR BANK NOT FUNCTIONING