Lincoln Electric SP-250 Welding System User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
F-16
TROUBLESHOOTING & REPAIR
F-16
IDEALARC SP-250
G1992 (code 9402 only):
5. Connect main input power to the
machine.
6. Turn the IDEALARC SP-250
ON/OFF POWER SWITCH to ON.
7. Make the following voltage tests at
Plug J3.
MAIN TRANSFORMER TEST
FIGURE F.1B - G1992 (Code 9402 Only) Control PC Board Main Transformer Test
Points. Note: Plugs J5 and J6 are on inboard non-component side of Control
Board.
SP-250 CONTROL
G1992
J2
J7
J4
J5
J3
J6
J9
J8
#208
(1J3)
#209 (2J3)
#206 (3J3)
#204A (5J3)
#202 (6J3)
#203
(7J3)
4. Locate the following leads on Plug
J3:
G2252:
PLUG
LOCATION
1J3
3J3
2J3
LEAD
#202
#203
#204 A
PLUG
LOCATION
6J3
7J3
5J3
LEAD
#202
#203
#204 A
FROM
LEAD
#202
(1J3)
#202
(1J3)
#203
(3J3)
TO
LEAD
#203
(3J3)
#204 A
(2J3)
#204 A
(2J3)
EXPECTED
VOLTAGE
30 VAC
15 VAC
15 VAC