Lincoln Electric SVM114-C Welder User Manual


 
ACCESSORIES
C-6C-6
LN-25™
TO GUN SWITCH
CONNECT LEADS TO
PINS "A" AND "C"
S12024-1 (L.E. PART NO.)
AMPHENOL AN3057-10 (OR EQUIV.)
S12020-6 (L.E. PART NO.)
AMPHENOL MS-3106A-18-11P (OR EQUIV.)
“A Dia. Hole”
To be Concentric to .749/.747
Wire Size Dia. Within .008 F.I.M.
.068 thru
5
64 .125 (
1
8 Drill)
1
16 (.062) .078 (
5
64 Drill)
.045 & .052 .062 (
1
16 Drill)
.023 thru .035 .055 (#54 Drill)
Drive Roll & Guide Tube Wire Sizes Used
Kit No.
T-13355-
3
32
5
64, .072 & .068
T-13355-
1
16
(1)
1
16, .062
T-13355-.052C .045, .052 Cored
T-13355-.052 .045, .052 Solid
T-15010.-.035S .023 thru .035 Solid
(1)
Can also be used for .052" wire
NOTE: Connector part with .749/.747 diameter should
be made from brass if it is to be part of the welding
current carrying circuit.
SWITCH REQUIREMENTS
1
2 Amp AC 24 Volts – Inductive
1
2 Amp DC 24 Volts – Inductive
CONNECTOR MUST
BE INSULATED
IN THIS AREA
STYLE "A"
STYLE "B"
LN-25 Connector for 1/16 (.062) through 5/64 Wire
LN-25 Cable Connector for .023 through .052 Wire
(For all other dimensions, see above)
2.00
1.25 MAX.
.749
D.
.747
.62
D.
.03 x 45
o
.03 x 45
o
.06R.
"A" DIA. HOLE
"A" DIA. HOLE
.295
.290
.252
.260
1.00
1.25
.180
.160
.495 MAX.
DIA.
GUN CABLE CONNECTOR REQUIREMENTS
TO PERMIT PROPER CONNECTION TO
LN-25™ WIRE FEEDER.
The following Figures C.1 and C.2 should serve as a guide to determine if a particular gun or switch
can be connected to the LN-25™.
FIGURE C.1
FIGURE C.2 – SWITCH REQUIREMENTS.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC