TROUBLESHOOTING AND REPAIR
F-26F-26
LN-25™
CONTACTOR TEST PROCEDURE
1. Open the case door. Remove the wire reel by
removing the retaining collar. See Figure F.5.
2. Remove the screws holding the control box
cover in place and remove the control box
cover. See Figure F.5.
3.Separate the two in-line connectors located behind
the reel stand assembly. See Figure F.13. For
codes 9812 and below, remove the two
contactor coil leads from the contactor PC
board. See Figure F.14.
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
CONTACTOR & CONTACTOR PC BOARD TEST (continued)
FIGURE F.13. CONTACTOR LEAD IN-LINE CONNECTORS.
IN-LINE
CONNECTORS