Lincoln Electric SVM141-A Welder User Manual


 
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
TROUBLESHOOTING & REPAIR
F-39 F-39
SQUARE WAVE TIG 275
MACHINE LOADED TO 275 AMPS
AT 31 VDC.
This is the typical AC output voltage
waveform generated from a properly
operating machine. Note that each
vertical division represents 20 volts
and that each horizontal division rep-
resents 2 milliseconds in time. The
machine was loaded with a resistance
grid bank.
NOTE: Scope probes connected at
machine output terminals: (+) probe to
electrode, (–) probe to work.
SCOPE SETTINGS
Volts/Div....................20 V/Div.
Horizontal Sweep.....2 ms/Div.
Coupling.............................DC
Trigger.........................Internal
0 V
2 ms
20 V
CAUTION
HIGH VOLTAGE / HIGH FREQUENCY can damage test equipment.
• Perform all voltage and waveform checks with high frequency circuit OFF.
• Perform High Frequency Disable Procedure.
TYPICAL OUTPUT VOLTAGE WAVEFORM - MACHINE LOADED
AC STICK MODE