POWER MIG 255
TROUBLESHOOTING & REPAIR
F-49 F-49
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
The liquid electrolite in the capacitors is toxic. Do not touch the capacitors with
any part of your body.
-------------------------------------------------------------------------------------------------------------------
WARNING
Service and repair should be performed by only Lincoln Electric factory trained
personnel. Unauthorized repairs performed on this equipment may result in danger
to the technician or machine operator and will invalidate your factory warranty. For
your safety and to avoid electrical shock, please observe all safety notes and pre-
cautions detailed throughout this manual.
If for any reason you do not understand the test procedures or are unable to per-
form the test / repairs safely, contact the Lincoln Electric Service Department for
electrical troubleshooting assistance before you proceed. Call 1-888-935-3877.
WARNING
CAPACITOR BANK
REMOVAL AND REPLACEMENT PROCEDURE
DESCRIPTION
This procedure will aid the technician in the removal and replacement of the Capacitor
Bank.
MATERIALS NEEDED
5/16 in. Nutdriver
3/8 in. Nutdriver
1/2 in. Open end wrench
3/8 in. Open end wrench
Wiring diagram