Lincoln Electric SVM179-B Welder User Manual


 
LOCK NUT
GAS SOLENOID
GAS HOSE
CONTROL BOX
CONTROL BOX COVER
" .+V,(%'("'.-'!(,
,,(%'("
+&(/%'+)%&'-)+(.+(CONTINUED)
)+(.+
1. Perform the Case Removal Procedure.
2. Remove the 5 #10-24 x .50 screws holding
the control box cover to access the contactor
leads. See Figure F.2.
3. Remove the 2 wires on the solenoid coil. See
wiring diagram.
4. Using the pliers remove the gas hose. Be
careful not to damage the hose. See <:HE8
.
5. Remove the lock nut holding the solenoid.
See <:HE8.
6. Remove the solenoid from the unit.
7. Install the new solenoid with the attached
hardware.
8. Reconnect the gas hose.
9. Reconnect the wires to the solenoid coil.
10. Replace the control box cover.
-+(.%,!((-"' +)"+
 