Lincoln Electric SVM 122-A Welder User Manual


 
CONNECTING THE LN-742 TO THE
IDEALARC DC-400 (14-PIN AMPHENOL)
1. Disconnect main AC input power to the Idealarc
DC-400.
2. Set the POWER toggle switch to the OFF (0) posi-
tion.
3. Connect the electrode cable from the LN-742 to
the “+” terminal of the welder. Connect the work
cable to the “-” terminal of the welder. Reverse
this hookup for negative polarity. See Figure C.11.
NOTE: Welding cable must be sized for the current
and duty cycle of the application.
4. Connect the K592 Control Cable to the 14-pin
amphenol on the IDEALARC DC-400 and to the
input cable plug on the LN-742. See Figure C.11.
5. Set the welder VOLTMETER switch to the desired
polarity, either DC (-) or DC (+).
6. Set the MODE switch to a CV (constant voltage)
position.
7. Adjust wire feed speed at the LN-742 and set the
welding voltage with the output ARC CONTROL to
a CV (constant voltage) position at the welder.
NOTE: If optional remote control is used, set the
OUTPUT CONTROL switch to the “Remote”
position and the OUTPUT TERMINALS switch
to the “Remote” position.
ACCESSORIES
C-13 C-13
LINCOLN
®
ELECTRIC
IDEALARC DC-400
Return to Section TOC Return to Section TOC Return to Section TOC Return to Section TOC
Return to Master TOC Return to Master TOC Return to Master TOC Return to Master TOC
FIGURE C.11 – IDEALARC DC-400/LN-742 CONNECTION DIAGRAM