TROUBLESHOOTING & REPAIR
F-25 F-25
LINCOLN
®
ELECTRIC
IDEALARC DC-400
Plug P1 PHASE ANGLE WINDING VOLTAGES
From Lead # To Lead # Expected VAC
201 204 21 VAC
202 204 21 VAC
203 204 21 VAC
MAIN TRANSFORMER (T1) VOLTAGE TEST (continued)
FIGURE F.8 – CONTROL BOARD PLUG P1 LOCATION
DC-400 CONTROL
G2588-X
Plug P1
#201
#202
#203
#204
Plug P3