Lowrance electronic EP-60R Stud Sensor User Manual


 
10
3. Select the tank you want to set up and press
MENU, which will open
the Tank Size window.
4. Use the
UP and DOWN keys to input the number of gallons the tank
will hold and press
MENU. Repeat steps 3 and 4 for each additional
tank. After all tanks have been set up, you will be directed to the main
display.
Boat Setup Reset
If you want to access the Setup screen (Boat Setup) after an engine-
tank configuration has been chosen you will have to reset the
configuration to default settings.
To reset engine tank configuration:
1. Press MENU, highlight SYSTEM SETUP and press MENU.
2. Choose
ENG/TANK and press MENU twice. The following message will
appear: Hit menu to reset Eng/Tnk.
3. Press
MENU. The Setup screen will appear with Boat Setup
highlighted.
Fuel Remaining Source (FRem Src)
The Fuel Remaining source function allows you to select the device
used to measure the amount of fuel remaining in the tank. It will be set
to fluid level by default.
To set Fuel Remaining Source to Fuel Flow (Eng/FFlow):
1. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
MENU. Select FUEL MNGR and press MENU.
2. Highlight
FREM SRC and press MENU. That will open the FRem Src
menu, which has two options: Eng/FFlow and Fuel level.
3. Select
ENG/FFLOW and press MENU. You can now view fuel remaining
data from the EP-60R.
EP-60R Fuel Flow Configuration
The LMF-200 can support up to three engines with one fuel flow sensor
for each engine. Each fuel flow has an internal menu with the following
options: Unset Engine, Change Engine (multiple engines only), Fuel
Warning, Reset and Reset Calibration.
To configure a fuel flow:
1. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
MENU.
2. Highlight
B. DEVICES and press MENU. After a few moments, the Bus
Devices list will appear.