Lowrance electronic EP-60R Stud Sensor User Manual


 
40
If you filled up the tank:
A. Press the FILL TANK button and press ENTER. The following message
will appear: Are you sure you wish to Fill Tank? Press
ENTER. Another
message will appear: Do you wish to re-calibrate the device? Highlight
NO and press ENTER.
If you did not fill up the tank:
B. Highlight FUEL ADDED and press ENTER to access the FUEL ADDED dialog
box. Use , to input the amount of fuel added to the tank and
press
ENTER. Select the ADD FUEL button and press ENTER. The following
message will appear: Are you sure you wish to Add Fuel? Highlight
YES
and press
ENTER.
6. Press
EXIT repeatedly to get back to the main display.
EP-60R Fuel Flow Calibration
The default calibration for the EP-60R Fuel Flow is adequate in most
cases, but if Fuel Used readings are off by more than 3 percent,
calibration is recommended.
Fuel Flow Accuracy
To check fuel flow accuracy you must overlay Fuel Used data on your
display to be able to check the accuracy of fuel information coming from
the fuel flow.
To overlay Fuel Used data on your screen:
1. Press MENU, select OVERLAY DATA and press ENTER.
2. If you currently have any overlay data on your screen, it will be
listed here. Select
(ENTER TO ADD) and press ENTER.
3. Highlight
NMEA 2000 or NETWORKING and press ENTER, which will open
the NMEA 2000 Devices list.
4. Select
EP-60R FUEL FLOW and press ENTER and a list of data options
will appear.
5. Highlight
FUEL USED and press ENTER.
6. Press
EXIT twice to return to the page display, where Fuel Used data
will be displayed on the screen.
To check fuel flow accuracy:
1. After selecting Fuel Used as overlay data, fill up your tank and press
MENU twice. Select NMEA 2000 or NETWORKING and press ENTER.
2. Highlight
FUEL MANAGEMENT and press ENTER. Select TANK LOCATION and
press
ENTER.
3. Select the tank location and press
ENTER.