To customize Fuel Manager page:
1. With the Fuel Manager page displayed on the main display, press
MENU, select CUSTOMIZE and press MENU.
2. Highlight
USD (Fuel Used) and press MENU. If your unit is configured
for more than one tank, the Select Tank menu will appear. (If your
engine-tank configuration is set for one tank, you will be directed to the
main display.)
3. Select the desired option and press
MENU. You will be directed to the
main display.
To check fuel flow accuracy:
1. Make sure your Fuel Remaining Source has been set to Fuel Flow
then fill up the fuel tank connected to the EP-60R Fuel Flow you want
to calibrate. Press
MENU, use the UP and DOWN keys to select SYSTEM
SETUP and press MENU.
2. Highlight
FUEL MNGR and press MENU. Select REFILL T. and press MENU.
If your unit is configured for more than one tank, the Select Tank menu
will open. Select the tank you refilled and press
MENU. (If your unit is
configured for one tank, you will be taken directly to the Recalibration
menu.)
3. The Recalibration (ReCal?) menu will appear with two options: Yes
and No. Select
NO and press MENU. The following message will appear:
Hit Menu if Tank filled up.
4. Press
MENU, which will direct you to the main display.
5. Take your boat out, but use only ONE engine — the engine
connected to the fuel flow. Burn at least 5 gallons of fuel, then fill up
the tank again, noting how much fuel was added to the tank. Check the
Fuel Management page for the fuel used figure calculated by the EP-
60R Fuel Flow.
6. Compare the amount of fuel you added when you filled up the tank
with the EP-60R Fuel Used figure. If the difference between these two
numbers is greater than 3 percent, you need to calibrate the unit.
To calibrate a fuel flow:
7. Press MENU, use the UP and DOWN keys to select SYSTEM SETUP and
press
MENU.
8. Highlight
FUEL MNGR and press MENU. Select REFILL T. and press MENU.
If your unit is configured for more than one tank, the Select Tank menu
will open. Select the tank you refilled and press
MENU. (If your unit is
configured for one tank, you will be taken directly to the Recalibration
menu.)