Toshiba e-Studio200 Work Light User Manual


 
e-STUDIO160/200/250 ADJUSTMENT ITEMS 1 - 2 December 2002 TOSHIBA TEC
Classification Error code Machine status
E41 Copier front cover or side cover is opened during copying
(Copier front cover, side cover, or transport cover of job
separator/offset tray/bridge cover is opened during
copying)
E42 Side cover of cassette 2 or cassette 3 is opened during
copying
E43 ADU is opened during copying
E44 Reserved
E45 Side cover of LCF is opened during copying
(e-STUDIO200/250 series)
E46 to E70 Reserved
E71 Original feeding jam at the feeding area of the ADF or
RADF
E72 Original transporting jam at the transporting area of the
ADF or RADF
E73 Original exiting jam at the exiting area of the ADF or RADF
E74 Original reversing jam at the reversing area of the RADF
E75 to EA0 Reserved
EA1 Paper transport delay jam
EA2 Paper transport stop jam
EA3 Paper remaining on the finisher transport path at power
ON
EA4 Finisher is opened during copying
EA5 Finisher staple jam
EA6 Finisher early arrival jam
EA7 Set transport jam before stapling
EA8 to EAE Reserved
EAF Stapled set transport jam
EB1 to EZ9 Reserved
- Process unit life nearly end
- Toner is nearly empty
- No toner cartridge
- Toner empty
- No process unit
- Process unit life end
- Upper tray of the job separator is full
- Lower tray of the job separator is full
- Offset tray is full
- Finisher tray is full (e-STUDIO200/250 series)
Paper jam if some cover is
opened
Paper transporting jam at the
ADF or RADF
Paper jam in the finisher
(e-STUDIO200/250 series)
Life end
Other operator calls