Toshiba e-Studio200 Work Light User Manual


 
December 2002 TOSHIBA TEC 1 - 63 e-STUDIO160/200/250 ADJUSTMENT ITEMS
(2) Place the scale (its end to the left side original scale) on the original glass and make an A3/LD 200%
copy.
(3) In order to correct the distance "F", which should be 20 ±0.5 mm from the leading edge of the paper,
adjust as follows.
Power ON
0
SET
SET
5
4 3 0
(Code)
0
Notes: 1. An increase in the value makes the image move to the trailing edge (0.126 mm/step).
2. Adjustment value is able to be input within the range of "120 - 136".
The default adjustment value is 128.
F
Copy movement direction
01-04-10
10
Power ON
0 5
SET Digital Keys SET INT START INT Power OFF
(Set the value) (Test copy)(Code)
3 0 5
c) Scanner secondary scanning deviation
(1) Set 0 for the top margin adjustment value.
or
START
or
START
or
START
Power OFF