Toshiba e-Studio200 Work Light User Manual


 
e-STUDIO160/200/250 UPDATING THE FIRMWARE 5 - 4 December 2002 TOSHIBA TEC
(6) Turn off the power.
(7) Remove the main recovery PWA and attach the rear cover.
Important: Only when the main data is downloaded after changing the main PWA.
In such a case, follows the step (a) through (g) described below.
(a) Holding down the [0] and [8] keys, turn on the power.
The copier enters the System mode.
(b) Enter “388” using the numeric keys and press the [SET]/[START] key.
The total counter value is baked up.
(c) Turn off the power.
(d) Holding down the [1], [3] and [*] keys, turn on the power and wait until "Please wait"
message is displayed.
(e) Turn off the power.
(f) Holding down the [1], [3] and [#] keys, turn on the power and wait until "Please wait"
message is displayed.
(g) Turn off the power.
(8) Holding down the [*], and [#] keys, turn on the power and wait until "Please wait" message is displayed.
The memory is cleared.
Important: After downloading the data, perform memory clear by turning the power ON while holding
down the [*] and [#] keys. This machine may not operate normally if this operation is not
performed. Also, if memory clear is performed by any operation other than the above, the
function setting data, user setting data, etc. may be erased. Do not perform any memory
clear operation other than the above.
(9) Turn off the power.