Toshiba e-Studio200 Work Light User Manual


 
December 2002 TOSHIBA TEC 2 - 7 e-STUDIO160/200/250 PREVENTIVE MAINTENANCE
*7. Drum gear/Cleaner paddle drive gear/Toner recovery auger drive gear
Confirm that toner or foreign matters is not stuck to the drum gear, cleaner paddle drive gear or
toner recover auger drive gear.
If stuck, remove the drum rear cover and clean the gear as required.
Drum rear cover
Drum assembly
Toner recovery auger
drive gear
Cleaner paddle
drive gear
Drum gear
2-7
*8. Doctor blade
Confirm that the doctor-sleeve gap is within the specified value. If not, adjust the gap. (For the
specified value and adjustment procedure, refer to section 1.13 “Adjustment of the doctor-sleeve
gap” on page 1-95.)
*9. Main charger wire
To clean the wire, use a charger cleaner.
*10. HVPS contacts (Feed roller contact/DEV. Contact/PU contact)/Ground plate
Use a cloth which should be soaked in water and then wrung strongly to clean the contacts surface.
*11. Pressure roller
Refer to “3.2 Checking and Cleaning of the Pressure Roller”.
*12. Heat roller
Refer to “3.4 Checking and Cleaning of the Heat Roller”.