e-STUDIO160/200/250 ADJUSTMENT ITEMS 1 - 58 December 2002 TOSHIBA TEC
(2) Measure the distance "C" which is the distance between the 5th line and 15th line from the leading
edge of the test print paper.
01-04-05
Print movement direction
155C
c) Main motor speed fine adjustment (Secondary scanning reproduction ratio of the printer unit)
(1) Make a test print and adjustment as in the following procedure.
(3) In order to set the distance "C" to 100 mm.
Notes: 1. A decrease in the value lengthen the distance "C" (0.1 %/step).
2. Adjustment value is able to be input within the range of 78 - 178.
The default adjustment value is 124.
* # * *
After 3 sec.
Enter SERVICE MODE
1 4 2
(Code)
SET
05:TEST MODE
Power ON
0 5
INTERRUPT PROGRAM
04:FUNCTION TEST
SET
02:PRINT TEST SET
STARTSET
Power OFFC/SSET
1
(Cassette) (Print end)
OK
NG
START
MAIN MENU
Digital Keys
SET
(Code)
INTERRUPT
4 2 1
or
(Set the value)
START
SET
or