Step 15: Wall Station Security Code Change and Programming
NOTE: The user must change the wall station’s security code before using the wall station.
This code setting sequence is only required the first time the wall station is used.
Overview: When changing the wall station’s security code, the user will have to hold the light button down for
approximately 10 seconds, then release the button momentarily, and finally hold the button down again for
approximately 5 seconds.
Changing the wall station’s security code:
1. Press and hold the wall station’s light button for approximately 10 seconds
until the wall station’s LED begins to blink rapidly. Once the LED starts
blinking release the wall station’s light button; the LED will turn
off.
2. Press and hold the wall station’s light button again (LED will light) for
approximately 5 seconds. After approximately 5 seconds the LED will begin
to blink on and off. Release the light button. The wall station’s
LED will blink on and off three times indicating a successful security code
change. The wall station is now ready to be programmed to the
opener.
Wall Station Programming
To program wall station:
1. Pull the emergency disconnect handle to the manual
door operated position (lower position). This is for safety
reasons.
2. On the front cover of the opener, press and release the
red program button; the opener will beep once, indicating
activation of the program mode. The opener will remain in
program mode for 30 seconds.
3. Press and hold the wall station light button until the opener
beeps once. The wall station is now programmed.
4. Return the emergency disconnect handle to the motor operated position (upper position).
No beeping response of the opener during the wall station programming indicates a programming failure.
Repeat programming steps 1-4.
NOTE: Programming failure can occur during the wall station programming if the wall station is too close to
the opener during the programming sequence. Perform the programming with a minimum of six feet between
the wall station and the opener.
NOTE: The opener can be activated by up to six remote control
devices (including wall station, transmitter, and keyless entry
devices.) If a seventh control is programmed, the first of the
programmed controls will be overridden and will no longer
activate the opener.
CAUTION: For safety reasons, manually disconnect using
the emergency disconnect handle prior to erasing remote
controls.
To clear programming of all remote control devices, press and
hold the opener’s program button for approximately ten
seconds. When the opener beeps three times, all remote
controls are erased.
HANDLE IN MOTOR
OPERATED POSTION
LIGHT BUTTON
LED
HANDLE IN MANUAL
OPERATED POSITION
OPENER
MOTOR IN UP
POSITION
RED PROGRAM
BUTTON