Wayne-Dalton 3651-372 Stud Sensor User Manual


 
Wall Station Operation
28
Momentarily pressing the up/down button activates
the door. If an out-of-balance condition causes the
door to stop while opening or reverses the door while
closing, applying constant pressure to the up/down
button until the door is fully open or closed will allow the opener
to move the door in this condition until the problem is corrected.
See Troubleshooting.
If a
severe out-of-balance condition causes the door to stop while
closing, the door can ONLY be lowered by the following procedure:
Multiple activations of the up/down button will lower the door
incrementally. Continue this process until the door is completely closed.
WARNING FAILURE TO MAKE ADJUSTMENTS/REPAIRS, COULD RESULT IN SEVERE OR
FATAL INJURY.
WARNING DO NOT USE THE EMERGENCY DISCONNECT TO LOWER THE DOOR. THE
DOOR COULD FALL RAPIDLY CAUSING A SEVERE OR FATAL INJURY.
The severe out-of-balance condition must be corrected before the door can be reactivated: Contact a qualified
service person immediately.
Momentarily pressing the light button turns on the light fixture. The light fixture will remain on until
either the light button is pressed again or the door is activated. The light fixture automatically turns on
with a door activation and remains on for five minutes thereafter. Pressing the light fixture button
before the five minutes has elapsed will turn off the light fixture. While the door is in motion, the light
button functions identically as the up/down button, stopping or reversing the door immediately.
Momentarily pressing the timer button causes a delayed activation of a stationary fully open door. The
opener will signal seven beeps (approx. 8 seconds) then beep constantly for two seconds prior to
closing the door. Allow enough time to exit the garage when the opener is in the timer mode. Pressing
any button, except for the profile button while the opener is beeping cancels the timer mode. NOTE:
The timer feature will only function with the door in the full open position. Pressing the timer
button with a stationary door in any other position will cause the opener to beep four times and the door will
not be activated. While the door is in motion, the timer button functions identically as the up/down button,
stopping or reversing the door immediately.
Pressing the pet button opens a closed door to a preset position between eight and thirty inches above
the floor, allowing pets to enter and exit the garage without the door being fully open. The door must
be fully closed to activate the pet open feature. Pressing the pet button with a stationary door in the
pet open position will cause the door to close. Pressing the up/down button while the door is in the pet
position will cause the door to open. While the door is in motion, the pet button functions identically
to the up/down button, stopping or reversing the door immediately. The pet feature allows for custom setting of the
pet position door height. See Step 19: Custom Settings.
NOTICE: A door in the “pet position” (open 8-30 inches) is not locked and should not be used as a secured
door position.
Pressing and holding the profile button for five (5) seconds will initiate the “Install Routine”. Refer
back to Step 16 for complete Install Routine instructions and functions.The wall station LED will
light while any wall station button remains pressed. See Maintenance section for battery replacement.
NOTE: Refer to Step 15 for wall station programming instructions.
LIGHT
LED
TIMER
PET
PROFILE
UP/DOWN